Data record std.tia-526-14-d.method.cord-grade-tradeoff

Verified 2026-10-25 Confidence: Medium

Clause 5.4 of ANSI/TIA-526-14-D (2023) explains that reference grade test cords introduce a measurement bias that must be accounted for but reduce uncertainty, while standard grade cords add no bias but can leave an uncertainty larger than the loss being measured; Table 4 tabulates expanded uncertainty by method, cord grade and measured loss.

ProvenanceANSI/TIA-526-14-D supports data record std.tia-526-14-d.method.cord-grade-tradeoff, which is cited on the entry ANSI/TIA-526-14-D.SOURCEANSI/TIA-526-14-DANSI/TIA-526-14-DLicensed standard, clause 5.4, 5.5DATA RECORDstd.tia-526-14-d.method.cord-grade-tradeoffstd.tia-526-14-d.method...Verified 2026-10-25ENTRYANSI/TIA-526-14-DANSI/TIA-526-14-DNo revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Provenance: the chain from source to entry.
StepItemDetail
SourceANSI/TIA-526-14-DLicensed standard, clause 5.4, 5.5
Data recordstd.tia-526-14-d.method.cord-grade-tradeoffVerified 2026-10-25
EntryANSI/TIA-526-14-DNo revisions
Subject
ANSI/TIA-526-14-D (Standards)
Kind
Method fact
Source
ANSI/TIA-526-14-D, 2023 edition, clause 5.4, 5.5, page 27, Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant, TIA.

History

Every recorded change to this data record, oldest first.
DateChange
2026-10-25created
2026-10-25revised
2026-10-25review_status unreviewed -> software_reviewed

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Data record std.tia-526-14-d.method.cord-grade-tradeoff." Fiber Optic Reference. 2026-10-25. https://www.fiberopticreference.com/data/std.tia-526-14-d.method.cord-grade-tradeoff/.