Data record std.tia-526-14-d.method.one-cord

Verified 2026-10-25 Confidence: High

Annex A of ANSI/TIA-526-14-D (2023) references the launch cord straight into the power meter, so the result includes both end connections and the cabling; when the meter cannot take the launch cord plug or the cord cannot stay on the source, the three-cord method may be used with its larger uncertainty.

ProvenanceANSI/TIA-526-14-D supports data record std.tia-526-14-d.method.one-cord, which is cited on the entry ANSI/TIA-526-14-D.SOURCEANSI/TIA-526-14-DANSI/TIA-526-14-DLicensed standard, clause Annex ADATA RECORDstd.tia-526-14-d.method.one-cordstd.tia-526-14-d.method...Verified 2026-10-25ENTRYANSI/TIA-526-14-DANSI/TIA-526-14-DNo revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Provenance: the chain from source to entry.
StepItemDetail
SourceANSI/TIA-526-14-DLicensed standard, clause Annex A
Data recordstd.tia-526-14-d.method.one-cordVerified 2026-10-25
EntryANSI/TIA-526-14-DNo revisions
Subject
ANSI/TIA-526-14-D (Standards)
Kind
Method fact
Source
ANSI/TIA-526-14-D, 2023 edition, clause Annex A, page 34, Optical Power Loss Measurements of Installed Multimode Fiber Cable Plant, TIA.

History

Every recorded change to this data record, oldest first.
DateChange
2026-10-25created
2026-10-25review_status unreviewed -> software_reviewed

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Data record std.tia-526-14-d.method.one-cord." Fiber Optic Reference. 2026-10-25. https://www.fiberopticreference.com/data/std.tia-526-14-d.method.one-cord/.