Data record std.tia-568-2-e.rule.category-8-not-a-superset

Verified 2026-10-25 Confidence: Medium

Over part of the frequency band, the NEXT and PSNEXT limits that ANSI/TIA-568.2-E sets for a Category 8 permanent link are less stringent than the augmented Category 6 permanent link limits. A result graded against the Category 8 limit therefore does not by itself show that the augmented Category 6 limit is met.

ProvenanceANSI/TIA-568.2-E supports data record std.tia-568-2-e.rule.category-8-not-a-superset, which is cited on the entry ANSI/TIA-568.2-E.SOURCEANSI/TIA-568.2-EANSI/TIA-568.2-ELicensed standard, clause 6.4.11, 6.4.12DATA RECORDstd.tia-568-2-e.rule.category-8-not-a-supersetstd.tia-568-2-e.rule.cat..Verified 2026-10-25ENTRYANSI/TIA-568.2-EANSI/TIA-568.2-ENo revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Provenance: the chain from source to entry.
StepItemDetail
SourceANSI/TIA-568.2-ELicensed standard, clause 6.4.11, 6.4.12
Data recordstd.tia-568-2-e.rule.category-8-not-a-supersetVerified 2026-10-25
EntryANSI/TIA-568.2-ENo revisions
Subject
ANSI/TIA-568.2-E (Standards)
Kind
Method fact
Source
ANSI/TIA-568.2-E, 2024 edition, clause 6.4.11, 6.4.12, page 82, Balanced Twisted-Pair Telecommunications Cabling and Components Standard, TIA.

History

Every recorded change to this data record, oldest first.
DateChange
2026-10-25created
2026-10-25revised
2026-10-25review_status unreviewed -> software_reviewed

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Data record std.tia-568-2-e.rule.category-8-not-a-superset." Fiber Optic Reference. 2026-10-25. https://www.fiberopticreference.com/data/std.tia-568-2-e.rule.category-8-not-a-superset/.