Annex E of ANSI/TIA-568.3-E (2022) recommends that a loss test record identify the date, personnel, instrument and its calibration, the fiber, the procedure and reference method, the launch condition and the loss in each direction at each wavelength, with OTDR records adding the cord details and trace files.

ProvenanceANSI/TIA-568.3-E supports data record std.tia-568-3-e.field-test.documentation, which is cited on the entry ANSI/TIA-568.3-E.SOURCEANSI/TIA-568.3-EANSI/TIA-568.3-ELicensed standard, clause E.6DATA RECORDstd.tia-568-3-e.field-test.documentationstd.tia-568-3-e.field-te..Verified 2026-10-25ENTRYANSI/TIA-568.3-EANSI/TIA-568.3-ENo revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Provenance: the chain from source to entry.
StepItemDetail
SourceANSI/TIA-568.3-ELicensed standard, clause E.6
Data recordstd.tia-568-3-e.field-test.documentationVerified 2026-10-25
EntryANSI/TIA-568.3-ENo revisions
Subject
ANSI/TIA-568.3-E (Standards)
Kind
Method fact
Source
ANSI/TIA-568.3-E, 2022 edition, clause E.6, page 95, Optical Fiber Cabling and Components Standard, TIA.