Data record std.tia-568-4-e.structure.other-connectors

Verified 2026-10-25 Confidence: Medium

ANSI/TIA-568.4-E (2022) requires a threaded SCTE plug on trunk, feeder and distribution cable and permits BNC connectors for quick connection when they meet the impedance-matched annex of IEC 61169-8.

ProvenanceANSI/TIA-568.4-E supports data record std.tia-568-4-e.structure.other-connectors, which is cited on the entry ANSI/TIA-568.4-E.SOURCEANSI/TIA-568.4-EANSI/TIA-568.4-ELicensed standard, clause 7.3.2; 7.3.3DATA RECORDstd.tia-568-4-e.structure.other-connectorsstd.tia-568-4-e.structur..Verified 2026-10-25ENTRYANSI/TIA-568.4-EANSI/TIA-568.4-ENo revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Provenance: the chain from source to entry.
StepItemDetail
SourceANSI/TIA-568.4-ELicensed standard, clause 7.3.2; 7.3.3
Data recordstd.tia-568-4-e.structure.other-connectorsVerified 2026-10-25
EntryANSI/TIA-568.4-ENo revisions
Subject
ANSI/TIA-568.4-E (Standards)
Kind
Standard scope
Source
ANSI/TIA-568.4-E, 2022 edition, clause 7.3.2; 7.3.3, page 30, Broadband Coaxial Cabling and Components Standard, TIA.

History

Every recorded change to this data record, oldest first.
DateChange
2026-10-25created
2026-10-25review_status unreviewed -> software_reviewed

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Data record std.tia-568-4-e.structure.other-connectors." Fiber Optic Reference. 2026-10-25. https://www.fiberopticreference.com/data/std.tia-568-4-e.structure.other-connectors/.