Data record std.tia-568-5.structure.permanent-link-topology

Verified 2026-10-25 Confidence: High

Clause 6.4.1 of ANSI/TIA-568.5 (2022) sets a lower connection count and a shorter cable length for the permanent link than for the channel, with the end connections counted inside the link and the tester cords outside it.

ProvenanceANSI/TIA-568.5 supports data record std.tia-568-5.structure.permanent-link-topology, which is cited on the entry ANSI/TIA-568.5-1.SOURCEANSI/TIA-568.5ANSI/TIA-568.5Licensed standard, clause 6.4.1DATA RECORDstd.tia-568-5.structure.permanent-link-topologystd.tia-568-5.structure...Verified 2026-10-25ENTRYANSI/TIA-568.5-1ANSI/TIA-568.5-1No revisions
Provenance. Where this record comes from and where it is used: the cited source, the record itself and the entry that cites it.
Provenance: the chain from source to entry.
StepItemDetail
SourceANSI/TIA-568.5Licensed standard, clause 6.4.1
Data recordstd.tia-568-5.structure.permanent-link-topologyVerified 2026-10-25
EntryANSI/TIA-568.5-1No revisions
Subject
ANSI/TIA-568.5-1 (Standards)
Kind
Standard scope
Source
ANSI/TIA-568.5, 2022 edition, clause 6.4.1, page 30, Balanced Single Twisted-Pair Telecommunications Cabling and Components Standard, TIA.

History

Every recorded change to this data record, oldest first.
DateChange
2026-10-25created
2026-10-25review_status unreviewed -> software_reviewed

Cite this page

Cite the governing standard for the fact itself; cite this page as the finding aid.

"Data record std.tia-568-5.structure.permanent-link-topology." Fiber Optic Reference. 2026-10-25. https://www.fiberopticreference.com/data/std.tia-568-5.structure.permanent-link-topology/.